{"id":155,"date":"2020-01-13T13:54:34","date_gmt":"2020-01-13T18:54:34","guid":{"rendered":"https:\/\/opentextbc.ca\/basicmotorcontrol\/chapter\/jog-circuits\/"},"modified":"2023-03-02T12:03:07","modified_gmt":"2023-03-02T17:03:07","slug":"jog-circuits","status":"publish","type":"chapter","link":"https:\/\/opentextbc.ca\/basicmotorcontrol\/chapter\/jog-circuits\/","title":{"raw":"Jog Circuits","rendered":"Jog Circuits"},"content":{"raw":"Sometimes called \u201c[pb_glossary id=\"265\"]inching[\/pb_glossary],\u201d jogging is the term given to the momentary energization of a motor only so long as an operator is pressing a button.\r\n\r\nA [pb_glossary id=\"266\"]jog circuit[\/pb_glossary] is a circuit that allows an operator to either start the motor or \u201c[pb_glossary id=\"264\"]jog[\/pb_glossary]\u201d the motor and are commonly used for motors controlling conveyor belts to allow for precise positioning of materials.\r\n\r\nAny [pb_glossary id=\"227\"]motor starter[\/pb_glossary] that is used to jog a motor will be subjected to repetitive [pb_glossary id=\"207\"]inrush currents[\/pb_glossary], which can cause overheating of the power contacts. If a motor is expected to be jogged more than five times in a minute, the motor starter should be increased in size and horsepower rating for this more severe operating condition.\r\n\r\nTo achieve a jog function, there are several common circuit designs, each with their own advantages and disadvantages. A common feature that all jog circuits have is that they have some method of disabling the <strong>holding contact<\/strong> used in the [pb_glossary id=\"271\"]three-wire circuit[\/pb_glossary]. This is usually accomplished by putting some component in [pb_glossary id=\"269\"]series[\/pb_glossary] with the holding contact, such as a [pb_glossary id=\"236\"]switch[\/pb_glossary] or momentary [pb_glossary id=\"235\"]pushbutton[\/pb_glossary].\r\n<h1>Jog Circuit with Selector Switch<\/h1>\r\n[caption id=\"attachment_154\" align=\"aligncenter\" width=\"1024\"]<img class=\"size-large wp-image-152\" src=\"https:\/\/opentextbc.ca\/accessibilitytoolkit\/wp-content\/uploads\/sites\/314\/2020\/01\/Jog-Selector-Switch-1-e1579709781367-1024x305.png\" alt=\"\" width=\"1024\" height=\"305\" \/> Selector switch jog control circuit[\/caption]\r\n\r\nThe most basic of the jog circuits, this is essentially a three-wire circuit with an <strong>SPST<\/strong> (single-pole, single-throw) switch connected in series with the holding contact.\r\n\r\nIn the closed position, the SPST switch offers no opposition to the flow of current and the circuit behaves the same as a standard three-wire circuit. The [pb_glossary id=\"229\"]normally open[\/pb_glossary] push button is acting as a \u201cstart\u201d or \u201crun\u201d button.\r\n\r\nIf the SPST switch is opened, then it has introduced an open in series with the [pb_glossary id=\"249\"]2-3 holding contacts[\/pb_glossary], effectively removing them from the circuit. Without the holding contact, the motor starter will only be energized as long as an operator is pressing the normally open pushbutton, which acts as a \u201cjog\u201d button in this position.\r\n<ul>\r\n \t<li>The main advantage of this circuit is the ease of installation and the cheapness of equipment.<\/li>\r\n \t<li>The main disadvantage is that you must change the position of your selector switch to change the function of your button.<\/li>\r\n<\/ul>\r\nhttps:\/\/media.bccampus.ca\/id\/0_pz1d1jlu?width=608&amp;height=402&amp;playerId=23449753\r\n<h1>Dangerous Jog Circuit<\/h1>\r\n[caption id=\"attachment_154\" align=\"aligncenter\" width=\"1024\"]<img class=\"size-large wp-image-153\" src=\"https:\/\/opentextbc.ca\/accessibilitytoolkit\/wp-content\/uploads\/sites\/314\/2020\/08\/Dangerous-Jog-1-e1579709662410-1024x287.png\" alt=\"\" width=\"1024\" height=\"287\" \/> Dangerous jog control circuit[\/caption]\r\n\r\nThe next jog circuit we will look at uses a four-contact momentary pushbutton as our \u201cJog\u201d button. This button has one set of [pb_glossary id=\"230\"]normally closed contacts[\/pb_glossary] which are wired in series with the 2-3 holding contact, and one set of normally open contacts which are in series with only the stop button and the motor starter.\r\n\r\nIn normal operation, the stop and start buttons provide their standard functions in a three-wire circuit, as the 2-3 holding contact is in series with the normally closed contacts of the jog button. If the jog button is pressed, the normally closed contacts will open and the normally open contacts will close, providing a path for current to energize the motor starter.\r\n\r\nWhen the motor starter is energized, all contacts associated with it will change their state, including the 2-3 holding contact, but because the jog button is being depressed the holding contact cannot maintain power to the starter. Once the\u00a0jog button is released the motor comes to a stop.\r\n\r\nThis circuit is sometimes referred to as the \"dangerous jog circuit\" for reasons which may appear obvious now. If the jog button's normally closed contacts are able to return to their normal condition before the motor starter\u2019s [pb_glossary id=\"263\"]armature[\/pb_glossary] has had a chance to drop out, then the coil will remain energized and the motor will continue to run. This is dangerous because if an operator pushes a jog button, expecting the motor to stop when they release the button, and the motor continues to run, it could introduce a hazard to a person caught off guard. In short, we never want machines to surprise people.\r\n<ul>\r\n \t<li>This circuit has the advantage of being simple to install and has separate buttons dedicated to starting and jogging the motor.<\/li>\r\n \t<li>The main disadvantage is the hazard introduced by the quick return of the jog button to its normal state.<\/li>\r\n<\/ul>\r\nhttps:\/\/media.bccampus.ca\/id\/0_599cbia4?width=608&amp;height=402&amp;playerId=23449753\r\n<h1>Jog Circuit with Control Relay<\/h1>\r\n[caption id=\"attachment_154\" align=\"aligncenter\" width=\"1024\"]<img class=\"size-large wp-image-154\" src=\"https:\/\/opentextbc.ca\/accessibilitytoolkit\/wp-content\/uploads\/sites\/314\/2020\/08\/Jog-With-Control-Relay-e1579656686160-1024x308.png\" alt=\"\" width=\"1024\" height=\"308\" \/> Jog circuit with control relay[\/caption]\r\n\r\nA more sophisticated jogging circuit uses a [pb_glossary id=\"262\"]control relay[\/pb_glossary] as shown in the figure above. Control relays behave just like motor starters but lack overload protection and power contacts. Control relays are loads that must be connected in [pb_glossary id=\"268\"]parallel[\/pb_glossary] with the motor starter to ensure they get their rated [pb_glossary id=\"219\"]voltage[\/pb_glossary].\r\n\r\nIn any [pb_glossary id=\"245\"]schematic diagram[\/pb_glossary], the current must find its way from Line 1 to Line 2 and energize only one load along the way. Switches offer either infinite [pb_glossary id=\"220\"]resistance[\/pb_glossary] when they are open or zero resistance when they are closed, so some device must limit the current to prevent short circuits. Notice that the current that passes through the control relay does not pass through the motor starter. This means that they will both get their rated value of voltage and pull in their armatures.\r\n\r\nAs a rule, we NEVER connect loads in series.\r\n\r\nUnder normal conditions, if the start button is pressed, current will be able to complete the circuit and energize the control relay. Once the relay is energized, the two normally open contacts associated with it will change their state and close. This will provide a path for current to energize the motor starter, closing the 2-3 holding contacts and running the motor.\r\n\r\nThe circuit will continue to operate as a standard three-wire circuit providing [pb_glossary id=\"215\"]low-voltage protection (LVP)[\/pb_glossary]\u00a0until either the stop button is pressed, or an [pb_glossary id=\"208\"]overload[\/pb_glossary] occurs.\r\n\r\nIf the jog button is pressed while the motor is running, there will be no change to the circuit.\r\n\r\nIf, however, the jog button is pressed while the motor is not running, it will provide a path for current to energize the motor starter. The current will not be able to energize the control relay, and so once the jog button is released, the starter drops out and the motor comes to a stop.\r\n<ul>\r\n \t<li>The advantage of this circuit lies in its safety and reliability. Having two separate buttons for \u201crun\u201d and \u201cjog\u201d functions increases ease of control for the operator.<\/li>\r\n \t<li>The disadvantage is the additional cost and installation time associated with the control relay and additional current drawn in the [pb_glossary id=\"242\"]control circuit[\/pb_glossary] due to the second coil.<\/li>\r\n<\/ul>\r\nhttps:\/\/media.bccampus.ca\/id\/0_3ujpky7k?width=608&amp;height=402&amp;playerId=23449753","rendered":"<p>Sometimes called \u201c<a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_265\">inching<\/a>,\u201d jogging is the term given to the momentary energization of a motor only so long as an operator is pressing a button.<\/p>\n<p>A <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_266\">jog circuit<\/a> is a circuit that allows an operator to either start the motor or \u201c<a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_264\">jog<\/a>\u201d the motor and are commonly used for motors controlling conveyor belts to allow for precise positioning of materials.<\/p>\n<p>Any <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_227\">motor starter<\/a> that is used to jog a motor will be subjected to repetitive <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_207\">inrush currents<\/a>, which can cause overheating of the power contacts. If a motor is expected to be jogged more than five times in a minute, the motor starter should be increased in size and horsepower rating for this more severe operating condition.<\/p>\n<p>To achieve a jog function, there are several common circuit designs, each with their own advantages and disadvantages. A common feature that all jog circuits have is that they have some method of disabling the <strong>holding contact<\/strong> used in the <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_271\">three-wire circuit<\/a>. This is usually accomplished by putting some component in <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_269\">series<\/a> with the holding contact, such as a <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_236\">switch<\/a> or momentary <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_235\">pushbutton<\/a>.<\/p>\n<h1>Jog Circuit with Selector Switch<\/h1>\n<figure id=\"attachment_154\" aria-describedby=\"caption-attachment-154\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-152\" src=\"https:\/\/opentextbc.ca\/accessibilitytoolkit\/wp-content\/uploads\/sites\/314\/2020\/01\/Jog-Selector-Switch-1-e1579709781367-1024x305.png\" alt=\"\" width=\"1024\" height=\"305\" srcset=\"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/01\/Jog-Selector-Switch-1-e1579709781367-1024x305.png 1024w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/01\/Jog-Selector-Switch-1-e1579709781367-300x89.png 300w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/01\/Jog-Selector-Switch-1-e1579709781367-768x229.png 768w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/01\/Jog-Selector-Switch-1-e1579709781367-1536x458.png 1536w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/01\/Jog-Selector-Switch-1-e1579709781367-2048x610.png 2048w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/01\/Jog-Selector-Switch-1-e1579709781367-65x19.png 65w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/01\/Jog-Selector-Switch-1-e1579709781367-225x67.png 225w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/01\/Jog-Selector-Switch-1-e1579709781367-350x104.png 350w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption id=\"caption-attachment-154\" class=\"wp-caption-text\">Selector switch jog control circuit<\/figcaption><\/figure>\n<p>The most basic of the jog circuits, this is essentially a three-wire circuit with an <strong>SPST<\/strong> (single-pole, single-throw) switch connected in series with the holding contact.<\/p>\n<p>In the closed position, the SPST switch offers no opposition to the flow of current and the circuit behaves the same as a standard three-wire circuit. The <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_229\">normally open<\/a> push button is acting as a \u201cstart\u201d or \u201crun\u201d button.<\/p>\n<p>If the SPST switch is opened, then it has introduced an open in series with the <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_249\">2-3 holding contacts<\/a>, effectively removing them from the circuit. Without the holding contact, the motor starter will only be energized as long as an operator is pressing the normally open pushbutton, which acts as a \u201cjog\u201d button in this position.<\/p>\n<ul>\n<li>The main advantage of this circuit is the ease of installation and the cheapness of equipment.<\/li>\n<li>The main disadvantage is that you must change the position of your selector switch to change the function of your button.<\/li>\n<\/ul>\n<p><iframe loading=\"lazy\" id=\"kaltura_player\" title=\"Jog with Selector Switch\" src=\"https:\/\/api.ca.kaltura.com\/p\/148\/sp\/14800\/embedIframeJs\/uiconf_id\/23449753\/partner_id\/148?iframeembed=true&#38;playerId=kaltura_player&#38;entry_id=0_pz1d1jlu&#38;flashvars[leadWithHTML5]=true&#38;flashvars[streamerType]=auto&#38;flashvars[localizationCode]=en&#38;flashvars[sideBarContainer.plugin]=true&#38;flashvars[sideBarContainer.position]=left&#38;flashvars[sideBarContainer.clickToClose]=true&#38;flashvars[chapters.plugin]=true&#38;flashvars[chapters.layout]=vertical&#38;flashvars[chapters.thumbnailRotator]=false&#38;flashvars[streamSelector.plugin]=true&#38;flashvars[EmbedPlayer.SpinnerTarget]=videoHolder&#38;flashvars[dualScreen.plugin]=true&#38;flashvars[Kaltura.addCrossoriginToIframe]=true&#38;wid=0_zu69ksky\" width=\"608\" height=\"402\" allowfullscreen=\"allowfullscreen\" sandbox=\"allow-downloads allow-forms allow-same-origin allow-scripts allow-top-navigation allow-pointer-lock allow-popups allow-modals allow-orientation-lock allow-popups-to-escape-sandbox allow-presentation allow-top-navigation-by-user-activation\" frameborder=\"0\"><\/iframe><\/p>\n<h1>Dangerous Jog Circuit<\/h1>\n<figure id=\"attachment_154\" aria-describedby=\"caption-attachment-154\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-153\" src=\"https:\/\/opentextbc.ca\/accessibilitytoolkit\/wp-content\/uploads\/sites\/314\/2020\/08\/Dangerous-Jog-1-e1579709662410-1024x287.png\" alt=\"\" width=\"1024\" height=\"287\" srcset=\"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Dangerous-Jog-1-e1579709662410-1024x287.png 1024w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Dangerous-Jog-1-e1579709662410-300x84.png 300w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Dangerous-Jog-1-e1579709662410-768x215.png 768w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Dangerous-Jog-1-e1579709662410-1536x430.png 1536w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Dangerous-Jog-1-e1579709662410-2048x573.png 2048w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Dangerous-Jog-1-e1579709662410-65x18.png 65w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Dangerous-Jog-1-e1579709662410-225x63.png 225w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Dangerous-Jog-1-e1579709662410-350x98.png 350w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption id=\"caption-attachment-154\" class=\"wp-caption-text\">Dangerous jog control circuit<\/figcaption><\/figure>\n<p>The next jog circuit we will look at uses a four-contact momentary pushbutton as our \u201cJog\u201d button. This button has one set of <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_230\">normally closed contacts<\/a> which are wired in series with the 2-3 holding contact, and one set of normally open contacts which are in series with only the stop button and the motor starter.<\/p>\n<p>In normal operation, the stop and start buttons provide their standard functions in a three-wire circuit, as the 2-3 holding contact is in series with the normally closed contacts of the jog button. If the jog button is pressed, the normally closed contacts will open and the normally open contacts will close, providing a path for current to energize the motor starter.<\/p>\n<p>When the motor starter is energized, all contacts associated with it will change their state, including the 2-3 holding contact, but because the jog button is being depressed the holding contact cannot maintain power to the starter. Once the\u00a0jog button is released the motor comes to a stop.<\/p>\n<p>This circuit is sometimes referred to as the &#8220;dangerous jog circuit&#8221; for reasons which may appear obvious now. If the jog button&#8217;s normally closed contacts are able to return to their normal condition before the motor starter\u2019s <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_263\">armature<\/a> has had a chance to drop out, then the coil will remain energized and the motor will continue to run. This is dangerous because if an operator pushes a jog button, expecting the motor to stop when they release the button, and the motor continues to run, it could introduce a hazard to a person caught off guard. In short, we never want machines to surprise people.<\/p>\n<ul>\n<li>This circuit has the advantage of being simple to install and has separate buttons dedicated to starting and jogging the motor.<\/li>\n<li>The main disadvantage is the hazard introduced by the quick return of the jog button to its normal state.<\/li>\n<\/ul>\n<p><iframe loading=\"lazy\" id=\"kaltura_player\" title=\"Bad jog circuit\" src=\"https:\/\/api.ca.kaltura.com\/p\/148\/sp\/14800\/embedIframeJs\/uiconf_id\/23449753\/partner_id\/148?iframeembed=true&#38;playerId=kaltura_player&#38;entry_id=0_599cbia4&#38;flashvars[leadWithHTML5]=true&#38;flashvars[streamerType]=auto&#38;flashvars[localizationCode]=en&#38;flashvars[sideBarContainer.plugin]=true&#38;flashvars[sideBarContainer.position]=left&#38;flashvars[sideBarContainer.clickToClose]=true&#38;flashvars[chapters.plugin]=true&#38;flashvars[chapters.layout]=vertical&#38;flashvars[chapters.thumbnailRotator]=false&#38;flashvars[streamSelector.plugin]=true&#38;flashvars[EmbedPlayer.SpinnerTarget]=videoHolder&#38;flashvars[dualScreen.plugin]=true&#38;flashvars[Kaltura.addCrossoriginToIframe]=true&#38;wid=0_uaxern6u\" width=\"608\" height=\"402\" allowfullscreen=\"allowfullscreen\" sandbox=\"allow-downloads allow-forms allow-same-origin allow-scripts allow-top-navigation allow-pointer-lock allow-popups allow-modals allow-orientation-lock allow-popups-to-escape-sandbox allow-presentation allow-top-navigation-by-user-activation\" frameborder=\"0\"><\/iframe><\/p>\n<h1>Jog Circuit with Control Relay<\/h1>\n<figure id=\"attachment_154\" aria-describedby=\"caption-attachment-154\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-154\" src=\"https:\/\/opentextbc.ca\/accessibilitytoolkit\/wp-content\/uploads\/sites\/314\/2020\/08\/Jog-With-Control-Relay-e1579656686160-1024x308.png\" alt=\"\" width=\"1024\" height=\"308\" srcset=\"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Jog-With-Control-Relay-e1579656686160-1024x308.png 1024w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Jog-With-Control-Relay-e1579656686160-300x90.png 300w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Jog-With-Control-Relay-e1579656686160-768x231.png 768w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Jog-With-Control-Relay-e1579656686160-1536x462.png 1536w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Jog-With-Control-Relay-e1579656686160-2048x616.png 2048w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Jog-With-Control-Relay-e1579656686160-65x20.png 65w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Jog-With-Control-Relay-e1579656686160-225x68.png 225w, https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-content\/uploads\/sites\/314\/2020\/08\/Jog-With-Control-Relay-e1579656686160-350x105.png 350w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption id=\"caption-attachment-154\" class=\"wp-caption-text\">Jog circuit with control relay<\/figcaption><\/figure>\n<p>A more sophisticated jogging circuit uses a <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_262\">control relay<\/a> as shown in the figure above. Control relays behave just like motor starters but lack overload protection and power contacts. Control relays are loads that must be connected in <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_268\">parallel<\/a> with the motor starter to ensure they get their rated <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_219\">voltage<\/a>.<\/p>\n<p>In any <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_245\">schematic diagram<\/a>, the current must find its way from Line 1 to Line 2 and energize only one load along the way. Switches offer either infinite <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_220\">resistance<\/a> when they are open or zero resistance when they are closed, so some device must limit the current to prevent short circuits. Notice that the current that passes through the control relay does not pass through the motor starter. This means that they will both get their rated value of voltage and pull in their armatures.<\/p>\n<p>As a rule, we NEVER connect loads in series.<\/p>\n<p>Under normal conditions, if the start button is pressed, current will be able to complete the circuit and energize the control relay. Once the relay is energized, the two normally open contacts associated with it will change their state and close. This will provide a path for current to energize the motor starter, closing the 2-3 holding contacts and running the motor.<\/p>\n<p>The circuit will continue to operate as a standard three-wire circuit providing <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_215\">low-voltage protection (LVP)<\/a>\u00a0until either the stop button is pressed, or an <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_208\">overload<\/a> occurs.<\/p>\n<p>If the jog button is pressed while the motor is running, there will be no change to the circuit.<\/p>\n<p>If, however, the jog button is pressed while the motor is not running, it will provide a path for current to energize the motor starter. The current will not be able to energize the control relay, and so once the jog button is released, the starter drops out and the motor comes to a stop.<\/p>\n<ul>\n<li>The advantage of this circuit lies in its safety and reliability. Having two separate buttons for \u201crun\u201d and \u201cjog\u201d functions increases ease of control for the operator.<\/li>\n<li>The disadvantage is the additional cost and installation time associated with the control relay and additional current drawn in the <a class=\"glossary-term\" aria-haspopup=\"dialog\" aria-describedby=\"definition\" href=\"#term_155_242\">control circuit<\/a> due to the second coil.<\/li>\n<\/ul>\n<p><iframe loading=\"lazy\" id=\"kaltura_player\" title=\"Jog with Control Relay\" src=\"https:\/\/api.ca.kaltura.com\/p\/148\/sp\/14800\/embedIframeJs\/uiconf_id\/23449753\/partner_id\/148?iframeembed=true&#38;playerId=kaltura_player&#38;entry_id=0_3ujpky7k&#38;flashvars[leadWithHTML5]=true&#38;flashvars[streamerType]=auto&#38;flashvars[localizationCode]=en&#38;flashvars[sideBarContainer.plugin]=true&#38;flashvars[sideBarContainer.position]=left&#38;flashvars[sideBarContainer.clickToClose]=true&#38;flashvars[chapters.plugin]=true&#38;flashvars[chapters.layout]=vertical&#38;flashvars[chapters.thumbnailRotator]=false&#38;flashvars[streamSelector.plugin]=true&#38;flashvars[EmbedPlayer.SpinnerTarget]=videoHolder&#38;flashvars[dualScreen.plugin]=true&#38;flashvars[Kaltura.addCrossoriginToIframe]=true&#38;wid=0_txv38rh0\" width=\"608\" height=\"402\" allowfullscreen=\"allowfullscreen\" sandbox=\"allow-downloads allow-forms allow-same-origin allow-scripts allow-top-navigation allow-pointer-lock allow-popups allow-modals allow-orientation-lock allow-popups-to-escape-sandbox allow-presentation allow-top-navigation-by-user-activation\" frameborder=\"0\"><\/iframe><\/p>\n<div class=\"glossary\"><span class=\"screen-reader-text\" id=\"definition\">definition<\/span><template id=\"term_155_265\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_265\"><div tabindex=\"-1\"><p>The term given to the momentary energization, at <em>reduced<\/em> voltage, of a motor only so long as an operator is pressing a button.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_266\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_266\"><div tabindex=\"-1\"><p>A control circuit that allows an operator to either start the motor or \u201cJog\u201d the motor only so long as a pushbutton is depressed, and are commonly used for motors controlling conveyor belts to allow for precise positioning of materials.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_264\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_264\"><div tabindex=\"-1\"><p>The term given to the momentary energization, at <em>full<\/em> voltage, of a motor only so long as an operator is pressing a button.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_227\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_227\"><div tabindex=\"-1\"><p>A device that controls the flow of electrical power to a motor. It is designed to safely start and stop a motor, and provide <strong>overload protection<\/strong>.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_207\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_207\"><div tabindex=\"-1\"><p>The initial high value of current produced when an inductive load is first energized.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_271\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_271\"><div tabindex=\"-1\"><p>In motor control terminology, a three-wire circuit utilizes a <strong>magnetic motor starter<\/strong> with a holding contact, along with momentary contact pushbuttons. A three-wire circuit provides <strong>low-voltage-protection<\/strong>.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_269\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_269\"><div tabindex=\"-1\"><p>In electrical terms, refers to a connection where current has only one path to flow.<\/p>\n<p>Loads connected in series will have the the same value of current flowing through them, and share the total voltage between them. Switches and overcurrent equipment is connected in series with equipment to control and protect it.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_236\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_236\"><div tabindex=\"-1\"><p>A device for making or breaking the connection in an electric circuit.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_235\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_235\"><div tabindex=\"-1\"><p>A momentary contact device that has a built in spring to return the button to its normal position once release. Available with either normally-open, normally-closed or both sets of contacts.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_229\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_229\"><div tabindex=\"-1\"><p>A contact that under normal conditions does not have continuity through it. When the contact changes its state it permits the flow of current by closing its contacts. Can be associated with pushbuttons, pilot devices or magnetic contactors.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_249\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_249\"><div tabindex=\"-1\"><p>Also known as a \"maintaining\" contact, these are the <strong>normally open<\/strong> contacts of a magnetic starter that are connected in parallel with the start button in a three-wire control circuit. When using the conventional NEMA numbering system, they get wire numbers \"2\" and \"3.\"<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_230\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_230\"><div tabindex=\"-1\"><p>A contact that under normal conditions has continuity through it. When the contact changes its state it interrupts the flow of current by opening its contacts. Can be associated with pushbuttons, pilot devices or magnetic contactors.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_263\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_263\"><div tabindex=\"-1\"><p>With respect to magnetic contactors, the armature or plunger is the movable part of the magnetic circuit. When a coil is energized the armature is pulled in, opening and\/or closing a set or sets of contacts.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_262\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_262\"><div tabindex=\"-1\"><p>Used when additional auxiliary contacts are needed in a control circuit, a control relay is a magnetic contactor which is <strong>not<\/strong> designed for the energization of motors, and <strong>does not<\/strong> have built in overload protection.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_268\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_268\"><div tabindex=\"-1\"><p>In electrical terms, refers to a connection where current has more than one path to flow.<\/p>\n<p>Loads connected in parallel will experience the same potential difference (voltage), but may draw different values of current depending upon their individual resistance.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_219\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_219\"><div tabindex=\"-1\"><p>The difference in electric potential between two points, which is defined as the work needed per unit of charge to move a test charge between the two points. It is measured in volts (V).<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_245\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_245\"><div tabindex=\"-1\"><p>A diagram that shows how a circuit works logically and electrically. It uses symbols to identify components and interconnecting lines to display the electrical continuity of a circuit. It is often used for troubleshooting purposes. Also known as a ladder diagram.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_220\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_220\"><div tabindex=\"-1\"><p>The opposition to the flow of current in an electric circuit, measured in ohms (\u03a9).<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_215\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_215\"><div tabindex=\"-1\"><p>Circuits with low-voltage protection will not automatically turn back on when voltage is restored following a power outage. Examples include the microwave or power tools.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_208\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_208\"><div tabindex=\"-1\"><p>A moderate and gradual rise in the value of current over a relatively long period of time that is caused by excessive amounts of current drawn by a motor due to too much load being put on the motor.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><template id=\"term_155_242\"><div class=\"glossary__definition\" role=\"dialog\" data-id=\"term_155_242\"><div tabindex=\"-1\"><p>In contrast to the Power Circuit, the Control Circuit consists of inputs, in the form of switches, pushbuttons or pilot devices, which when activated, can either directly, or through a magnetic motor starter, energize a load. The Control Circuit often operates at a lower voltage than the Power Circuit for safety and ease of installation.<\/p>\n<\/div><button><span aria-hidden=\"true\">&times;<\/span><span class=\"screen-reader-text\">Close definition<\/span><\/button><\/div><\/template><\/div>","protected":false},"author":90,"menu_order":11,"template":"","meta":{"pb_show_title":"on","pb_short_title":"","pb_subtitle":"","pb_authors":[],"pb_section_license":""},"chapter-type":[],"contributor":[],"license":[],"class_list":["post-155","chapter","type-chapter","status-publish","hentry"],"part":121,"_links":{"self":[{"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/pressbooks\/v2\/chapters\/155","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/pressbooks\/v2\/chapters"}],"about":[{"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/wp\/v2\/types\/chapter"}],"author":[{"embeddable":true,"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/wp\/v2\/users\/90"}],"version-history":[{"count":5,"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/pressbooks\/v2\/chapters\/155\/revisions"}],"predecessor-version":[{"id":452,"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/pressbooks\/v2\/chapters\/155\/revisions\/452"}],"part":[{"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/pressbooks\/v2\/parts\/121"}],"metadata":[{"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/pressbooks\/v2\/chapters\/155\/metadata\/"}],"wp:attachment":[{"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/wp\/v2\/media?parent=155"}],"wp:term":[{"taxonomy":"chapter-type","embeddable":true,"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/pressbooks\/v2\/chapter-type?post=155"},{"taxonomy":"contributor","embeddable":true,"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/wp\/v2\/contributor?post=155"},{"taxonomy":"license","embeddable":true,"href":"https:\/\/opentextbc.ca\/basicmotorcontrol\/wp-json\/wp\/v2\/license?post=155"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}