{"id":175,"date":"2022-01-06T13:52:30","date_gmt":"2022-01-06T18:52:30","guid":{"rendered":"https:\/\/opentextbc.ca\/plumbing3e\/back-matter\/self-test-answer-keys\/"},"modified":"2022-01-06T13:52:30","modified_gmt":"2022-01-06T18:52:30","slug":"self-test-answer-keys","status":"publish","type":"back-matter","link":"https:\/\/opentextbc.ca\/plumbing3e\/back-matter\/self-test-answer-keys\/","title":{"raw":"Appendix 1: Self-Test Answer Keys","rendered":"Appendix 1: Self-Test Answer Keys"},"content":{"raw":"<h1>Competency E1<\/h1>\n<h2>Self-Test 1<\/h2>\n<ol class=\"threecolumn\">\n \t<li>C<\/li>\n \t<li>B<\/li>\n \t<li>C<\/li>\n \t<li>A<\/li>\n \t<li>A<\/li>\n<\/ol>\n<h2>Self-Test 2<\/h2>\n<ol class=\"threecolumn\">\n \t<li>B<\/li>\n \t<li>C<\/li>\n \t<li>A<\/li>\n \t<li>B<\/li>\n \t<li>D<\/li>\n \t<li>D<\/li>\n<\/ol>\n<h2>Self-Test 3<\/h2>\n<ol class=\"threecolumn\">\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>C<\/li>\n \t<li>D<\/li>\n \t<li>B<\/li>\n \t<li>A<\/li>\n \t<li>A<\/li>\n \t<li>B<\/li>\n<\/ol>\n<h1>Competency E2<\/h1>\n<h2>Self-Test 1<\/h2>\n<ol class=\"threecolumn\">\n \t<li>D<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>D<\/li>\n \t<li>B<\/li>\n \t<li>C<\/li>\n \t<li>A<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>A<\/li>\n \t<li>C<\/li>\n<\/ol>\n<h1>Competency E3<\/h1>\n<h2>Self-Test 1<\/h2>\n<ol class=\"threecolumn\">\n \t<li>A<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>A<\/li>\n \t<li>D<\/li>\n \t<li>D<\/li>\n \t<li>B<\/li>\n \t<li>\u00a0C, D, A, B<\/li>\n \t<li>B<\/li>\n \t<li>A<\/li>\n \t<li>A<\/li>\n \t<li>A<\/li>\n \t<li>A<\/li>\n<\/ol>\n<h2>Self-Test 2<\/h2>\n<ol>\n \t<li>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Natural Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Steel<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure<\/th>\n<td style=\"width: 50%;\">1.75 kPa<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">A.2 (b) Metric<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">250 Pa<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">12 m<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">12 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">35 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">10 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex]\u00a0in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">45 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n \t<li>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Propane Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Copper Tube<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure<\/th>\n<td style=\"width: 50%;\">11 in<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">B.6 (a) Imperial<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">1 in<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">35 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">40 ft<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">100 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{5}{8}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">40 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">140 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n \t<li>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Type of Gas<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Natural Gas - Low Pressure Systems<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Natural Gas - High Pressure Systems<\/th>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 33.3333%;\">Copper Tube<\/td>\n<td style=\"width: 33.3333%;\">Copper Tube<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">System Pressure<\/th>\n<td style=\"width: 33.3333%;\">7 in<\/td>\n<td style=\"width: 33.3333%;\">2 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 33.3333%;\">A.9 (a) Imperial<\/td>\n<td style=\"width: 33.3333%;\">A.10 (a) Imperial<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 33.3333%;\">1 in<\/td>\n<td style=\"width: 33.3333%;\">1 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 33.3333%;\">A = 10 ft\n\nB = 20 ft\n\nC = 40 ft<\/td>\n<td style=\"width: 33.3333%;\">40 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 33.3333%;\">A = 10 ft\n\nB = 20 ft\n\nC = 40 ft<\/td>\n<td style=\"width: 33.3333%;\">40 ft<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%; height: 90px;\" border=\"0\">\n<tbody>\n<tr style=\"height: 18px;\">\n<th style=\"width: 25%; height: 18px;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 25%; height: 18px;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 25%; height: 18px;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr style=\"height: 18px;\">\n<td style=\"width: 25%; height: 18px;\">A<\/td>\n<td style=\"width: 25%; height: 18px;\">100 MBH<\/td>\n<td style=\"width: 25%; height: 18px;\">[latex]\\frac{5}{8}[\/latex] in OD copper tube<\/td>\n<\/tr>\n<tr style=\"height: 18px;\">\n<td style=\"width: 25%; height: 18px;\">B<\/td>\n<td style=\"width: 25%; height: 18px;\">40 MBH<\/td>\n<td style=\"width: 25%; height: 18px;\">[latex]\\frac{1}{2}[\/latex] in OD copper tube<\/td>\n<\/tr>\n<tr style=\"height: 18px;\">\n<td style=\"width: 25%; height: 18px;\">C<\/td>\n<td style=\"width: 25%; height: 18px;\">40 MBH<\/td>\n<td style=\"width: 25%; height: 18px;\">[latex]\\frac{5}{8}[\/latex] in OD copper tube<\/td>\n<\/tr>\n<tr style=\"height: 18px;\">\n<td style=\"width: 25%; height: 18px;\">D<\/td>\n<td style=\"width: 25%; height: 18px;\">180 MBH<\/td>\n<td style=\"width: 25%; height: 18px;\">[latex]\\frac{1}{2}[\/latex] in OD copper tube<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<\/ol>\n<h2>Self-Test 3<\/h2>\n<ol>\n \t<li>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Natural Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Welded carbon with forged fittings<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure<\/th>\n<td style=\"width: 50%;\">5 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">A.5 (a) Imperial<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">2.5 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">160 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">200 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\">Proofed longest (ELR)<\/th>\n<td style=\"width: 50%;\">187.17 ft<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">1,500 MBH<\/td>\n<td style=\"width: 33.3333%;\">1 in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">3,000 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]1 \\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">4,500 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<span style=\"text-decoration: underline;\">Proof of C-A<\/span>\n[latex]\\begin{array}{ll}\\text{4 - 1\u00bd\u2033 welded 90\u00b0 @ 1.61 feet}&amp;=6.44 \\text{ feet} \\\\ \\text{2 - 1\u00bd\u2033 welded tee @ 6.04 feet}&amp; = 12.08 \\text{ feet} \\\\ \\text{2 - 1\u2033 welded 90\u00b0 @ 2.06 feet}&amp;=2.10 \\text{ feet} \\\\ \\text{1 - 1\u2033 valve @ 2.62 feet}&amp; = 2.62\\text{ feet} \\\\ \\text{1 - 1\u2033 welded tee @ 3.93 feet}&amp; = \\underline{3.93 \\text{ feet}} \\\\ \\text{Equivalent Fitting Length} &amp; = 27.17\\text{ feet} \\\\ \\text{Measured Length C-A} &amp; = \\underline{160.00 \\text{ feet}} \\\\ \\text{Longest Equivalent Length of Run (ELR)} &amp;= 187.17\\text{ feet} \\end{array}[\/latex]\n\nThe longest ELR is 187.17 feet, so the 200 ft code zone was correct.<\/li>\n \t<li>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Natural Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Welded carbon with forged fittings<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure<\/th>\n<td style=\"width: 50%;\">34 kPa<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">A.5 (b) Metric<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">17 kPa<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">30 m<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">45 m<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\">Proofed Longest (ELR)<\/th>\n<td style=\"width: 50%;\">41.03 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">293 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">805 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">3,000 kW<\/td>\n<td style=\"width: 33.3333%;\">2 in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">D<\/td>\n<td style=\"width: 33.3333%;\">1,170 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">E<\/td>\n<td style=\"width: 33.3333%;\">4,170 kW<\/td>\n<td style=\"width: 33.3333%;\">2 in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">F<\/td>\n<td style=\"width: 33.3333%;\">4,975 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]2\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">G<\/td>\n<td style=\"width: 33.3333%;\">5,268 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]2\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<span style=\"text-decoration: underline;\">Proof of G - B<\/span>\n[latex]\\begin{array}{ll}\\text{2 - 2\u00bd\u2033 welded 90\u00b0 @ 0.75m}&amp;=1.50 \\text{ m} \\\\ \\text{2 - 1\u00bd\u2033 welded tees @ 2.82 m}&amp; = 5.64\\text{ m} \\\\ \\text{3 - 1\u00bc\u2033 welded 90\u00b0 @ 0.42 m}&amp;=1.26 \\text{ m} \\\\ \\text{1 - 1\u00bc\u2033 valve @ 1.05 m}&amp; = 1.05\\text{ m} \\\\ \\text{1 - 1\u00bc\u2033 welded tee @ 1.58 m}&amp; = \\underline{1.58 \\text{ m}} \\\\ \\text{Equivalent Fitting Length} &amp; = 11.03\\text{ m} \\\\ \\text{Measured Length C-A} &amp; = \\underline{30.00 \\text{ m}} \\\\ \\text{Equivalent Length of Run (ELR)} &amp;= 41.03\\text{ m} \\end{array}[\/latex]\n\nAdditional proofs\n\n<span style=\"text-decoration: underline;\">Proof of G-C<\/span>\n[latex]\\begin{array}{ll}\\text{2 - 2\u00bd\u2033 welded 90\u00b0 @ 0.75m}&amp;=1.50 \\text{ m} \\\\ \\text{1 - 2\u00bd\u2033 welded tees @ 2.82 m}&amp; = 2.82\\text{ m} \\\\ \\text{3 - 2\u2033 welded 90\u00b0 @ 0.63 m}&amp;=1.89\\text{ m} \\\\ \\text{1 - 2\u2033 valve @ 1.58 m}&amp; = 1.58\\text{ m} \\\\ \\text{2 - 2\u2033 welded tees @ 2.36 m}&amp; = \\underline{4.72 \\text{ m}} \\\\ \\text{Equivalent Fitting Length} &amp; = 12.51\\text{ m} \\\\ \\text{Measured Length C-A} &amp; = \\underline{22.00 \\text{ m}} \\\\ \\text{Equivalent Length of Run (ELR)} &amp;= 34.51\\text{ m} \\end{array}[\/latex]\n\n<span style=\"text-decoration: underline;\">Proof of G-D\n<\/span>[latex]\\begin{array}{ll}\\text{2 - 2\u00bd\u2033 welded 90\u00b0 @ 0.75m}&amp;=1.50 \\text{ m} \\\\ \\text{1 - 2\u00bd\u2033 welded tees @ 2.82 m}&amp; = 2.82\\text{ m} \\\\ \\text{3 - 1\u00bc\u2033 welded 90\u00b0 @ 0.42 m}&amp;=1.26\\text{ m} \\\\ \\text{1 - 1\u00bc\u2033 valve @ 1.05 m}&amp; = 1.05\\text{ m} \\\\ \\text{1 - 1\u00bc\u2033 welded tee @ 1.58 m}&amp; = \\underline{1.58\\text{ m}} \\\\ \\text{Equivalent Fitting Length} &amp; = 8.21\\text{ m} \\\\ \\text{Measured Length C-A} &amp; = \\underline{25.00 \\text{ m}} \\\\ \\text{Equivalent Length of Run (ELR)} &amp;= 33.21\\text{ m} \\end{array}[\/latex]\n\nThe longest ELR is 41.03 metres, so the 45 meter code zone was correct.<\/li>\n \t<li>7\u2033 WC Piping System:\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Natural Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Screwed carbon steel pipe<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure - 7\u2033 WS<\/th>\n<td style=\"width: 50%;\">7\u2033 WC<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">A.2 (a) Imperial<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">1\u2033 WC<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">93 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">100 ft<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">100 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">75 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">175 MBH<\/td>\n<td style=\"width: 33.3333%;\">1 in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n2 PSG Piping System:\n<table style=\"border-collapse: collapse; width: 100%; height: 112px;\" border=\"0\">\n<tbody>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%; height: 16px;\">Natural Gas<\/td>\n<\/tr>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%; height: 16px;\">Screwed carbon steel pipe<\/td>\n<\/tr>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">System Pressure - 2 PSI<\/th>\n<td style=\"width: 50%; height: 16px;\">2 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\">Selected Pressure Drop - 1 PSI<\/th>\n<td style=\"width: 50%;\">1 psig<\/td>\n<\/tr>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%; height: 16px;\">A.3 (a) Imperial<\/td>\n<\/tr>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%; height: 16px;\">83 ft<\/td>\n<\/tr>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%; height: 16px;\">90 ft<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">1<\/td>\n<td style=\"width: 33.3333%;\">300 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">2<\/td>\n<td style=\"width: 33.3333%;\">150 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">3<\/td>\n<td style=\"width: 33.3333%;\">450 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n5 PSG Piping System\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Natural Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Screwed carbon steel pipe<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure - 5 PSI<\/th>\n<td style=\"width: 50%;\">5 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">A.5 (a) Imperial<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">2.5 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">84 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">125 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\">Proofed Longest (ELR)<\/th>\n<td style=\"width: 50%;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">5,000 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">450 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">5,450 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">D<\/td>\n<td style=\"width: 33.3333%;\">175 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">E<\/td>\n<td style=\"width: 33.3333%;\">5,625 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\nProof of G - B\n[latex]\\begin{array}{ll}\\text{5 - 1\u00bc\u2033 screwed 90\u00b0 @ 3.45 ft}&amp;=17.25 \\text{ ft} \\\\ \\text{1 - 1\u00bc\u2033 valve @ 3.45 ft}&amp; = 3.45 \\text{ ft} \\\\ \\text{2 - 1\u00bc\u2033 screwed tees @ 6.90 ft}&amp;=\\underline{13.80 \\text{ ft}} \\\\ \\text{Equivalent Fitting Length} &amp; = 34.50\\text{ feet} \\\\ \\text{Measured Length C-A} &amp; = \\underline{84.00 \\text{ feet}} \\\\ \\text{Equivalent Length of Run (ELR)} &amp;= 118.50\\text{ feet} \\end{array}[\/latex]\n\nThe longest ELR is 118.50 feet, so the 125 ft code zone was correct.<\/li>\n<\/ol>\n<h1>Competency E5<\/h1>\n<h2>Self-Test 1<\/h2>\n<ol class=\"threecolumn\">\n \t<li>A<\/li>\n \t<li>D<\/li>\n \t<li>A<\/li>\n \t<li>C<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>C<\/li>\n \t<li>D<\/li>\n \t<li>B<\/li>\n<\/ol>\n<h2>Self-Test 2<\/h2>\n<ol class=\"twocolumn\">\n \t<li>A<\/li>\n \t<li>B<\/li>\n \t<li>A<\/li>\n \t<li>B<\/li>\n \t<li>C<\/li>\n \t<li>A<\/li>\n \t<li>Match the names of the burner parts to their\nlettered locations\n<ul>\n \t<li>Venturi D<\/li>\n \t<li>Mixing Tube C<\/li>\n \t<li>Burner Ports A<\/li>\n \t<li>Orifice E<\/li>\n \t<li>Burner Head B<\/li>\n \t<li>Primary air openings F<\/li>\n<\/ul>\n<\/li>\n \t<li>B<\/li>\n \t<li>A<\/li>\n \t<li>C<\/li>\n \t<li>C<\/li>\n \t<li>A<\/li>\n \t<li>A<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n<\/ol>\n<h2>Self-Test 3<\/h2>\n<ol class=\"threecolumn\">\n \t<li>C<\/li>\n \t<li>B<\/li>\n \t<li>D<\/li>\n \t<li>D<\/li>\n \t<li>B<\/li>\n \t<li>D<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>C<\/li>\n \t<li>D<\/li>\n \t<li>B<\/li>\n \t<li>A<\/li>\n \t<li>C<\/li>\n \t<li>B<\/li>\n \t<li>A<\/li>\n<\/ol>\n<h1>Competency E6<\/h1>\n<h2>Self-Test 1<\/h2>\n<ol class=\"threecolumn\">\n \t<li>D<\/li>\n \t<li>C<\/li>\n \t<li>D<\/li>\n \t<li>B<\/li>\n<\/ol>\n<h2>Self-Test 2<\/h2>\n<ol class=\"threecolumn\">\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>C<\/li>\n \t<li>B<\/li>\n \t<li>A<\/li>\n \t<li>A<\/li>\n \t<li>A<\/li>\n \t<li>C<\/li>\n<\/ol>\n<h2>Self-Test 3<\/h2>\n<ol class=\"threecolumn\">\n \t<li>C<\/li>\n \t<li>C<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n \t<li>C<\/li>\n \t<li>D<\/li>\n \t<li>B<\/li>\n \t<li>B<\/li>\n<\/ol>","rendered":"<h1>Competency E1<\/h1>\n<h2>Self-Test 1<\/h2>\n<ol class=\"threecolumn\">\n<li>C<\/li>\n<li>B<\/li>\n<li>C<\/li>\n<li>A<\/li>\n<li>A<\/li>\n<\/ol>\n<h2>Self-Test 2<\/h2>\n<ol class=\"threecolumn\">\n<li>B<\/li>\n<li>C<\/li>\n<li>A<\/li>\n<li>B<\/li>\n<li>D<\/li>\n<li>D<\/li>\n<\/ol>\n<h2>Self-Test 3<\/h2>\n<ol class=\"threecolumn\">\n<li>B<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>C<\/li>\n<li>D<\/li>\n<li>B<\/li>\n<li>A<\/li>\n<li>A<\/li>\n<li>B<\/li>\n<\/ol>\n<h1>Competency E2<\/h1>\n<h2>Self-Test 1<\/h2>\n<ol class=\"threecolumn\">\n<li>D<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>D<\/li>\n<li>B<\/li>\n<li>C<\/li>\n<li>A<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>A<\/li>\n<li>C<\/li>\n<\/ol>\n<h1>Competency E3<\/h1>\n<h2>Self-Test 1<\/h2>\n<ol class=\"threecolumn\">\n<li>A<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>A<\/li>\n<li>D<\/li>\n<li>D<\/li>\n<li>B<\/li>\n<li>\u00a0C, D, A, B<\/li>\n<li>B<\/li>\n<li>A<\/li>\n<li>A<\/li>\n<li>A<\/li>\n<li>A<\/li>\n<\/ol>\n<h2>Self-Test 2<\/h2>\n<ol>\n<li>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Natural Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Steel<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure<\/th>\n<td style=\"width: 50%;\">1.75 kPa<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">A.2 (b) Metric<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">250 Pa<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">12 m<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">12 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">35 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">10 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex]\u00a0in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">45 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<li>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Propane Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Copper Tube<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure<\/th>\n<td style=\"width: 50%;\">11 in<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">B.6 (a) Imperial<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">1 in<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">35 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">40 ft<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">100 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{5}{8}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">40 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">140 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<li>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Type of Gas<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Natural Gas &#8211; Low Pressure Systems<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Natural Gas &#8211; High Pressure Systems<\/th>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 33.3333%;\">Copper Tube<\/td>\n<td style=\"width: 33.3333%;\">Copper Tube<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">System Pressure<\/th>\n<td style=\"width: 33.3333%;\">7 in<\/td>\n<td style=\"width: 33.3333%;\">2 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 33.3333%;\">A.9 (a) Imperial<\/td>\n<td style=\"width: 33.3333%;\">A.10 (a) Imperial<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 33.3333%;\">1 in<\/td>\n<td style=\"width: 33.3333%;\">1 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 33.3333%;\">A = 10 ft<\/p>\n<p>B = 20 ft<\/p>\n<p>C = 40 ft<\/td>\n<td style=\"width: 33.3333%;\">40 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 33.3333%; vertical-align: top;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 33.3333%;\">A = 10 ft<\/p>\n<p>B = 20 ft<\/p>\n<p>C = 40 ft<\/td>\n<td style=\"width: 33.3333%;\">40 ft<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%; height: 90px;\">\n<tbody>\n<tr style=\"height: 18px;\">\n<th style=\"width: 25%; height: 18px;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 25%; height: 18px;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 25%; height: 18px;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr style=\"height: 18px;\">\n<td style=\"width: 25%; height: 18px;\">A<\/td>\n<td style=\"width: 25%; height: 18px;\">100 MBH<\/td>\n<td style=\"width: 25%; height: 18px;\">[latex]\\frac{5}{8}[\/latex] in OD copper tube<\/td>\n<\/tr>\n<tr style=\"height: 18px;\">\n<td style=\"width: 25%; height: 18px;\">B<\/td>\n<td style=\"width: 25%; height: 18px;\">40 MBH<\/td>\n<td style=\"width: 25%; height: 18px;\">[latex]\\frac{1}{2}[\/latex] in OD copper tube<\/td>\n<\/tr>\n<tr style=\"height: 18px;\">\n<td style=\"width: 25%; height: 18px;\">C<\/td>\n<td style=\"width: 25%; height: 18px;\">40 MBH<\/td>\n<td style=\"width: 25%; height: 18px;\">[latex]\\frac{5}{8}[\/latex] in OD copper tube<\/td>\n<\/tr>\n<tr style=\"height: 18px;\">\n<td style=\"width: 25%; height: 18px;\">D<\/td>\n<td style=\"width: 25%; height: 18px;\">180 MBH<\/td>\n<td style=\"width: 25%; height: 18px;\">[latex]\\frac{1}{2}[\/latex] in OD copper tube<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<\/ol>\n<h2>Self-Test 3<\/h2>\n<ol>\n<li>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Natural Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Welded carbon with forged fittings<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure<\/th>\n<td style=\"width: 50%;\">5 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">A.5 (a) Imperial<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">2.5 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">160 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">200 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\">Proofed longest (ELR)<\/th>\n<td style=\"width: 50%;\">187.17 ft<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">1,500 MBH<\/td>\n<td style=\"width: 33.3333%;\">1 in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">3,000 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]1 \\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">4,500 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"text-decoration: underline;\">Proof of C-A<\/span><br \/>\n[latex]\\begin{array}{ll}\\text{4 - 1\u00bd\u2033 welded 90\u00b0 @ 1.61 feet}&=6.44 \\text{ feet} \\\\ \\text{2 - 1\u00bd\u2033 welded tee @ 6.04 feet}& = 12.08 \\text{ feet} \\\\ \\text{2 - 1\u2033 welded 90\u00b0 @ 2.06 feet}&=2.10 \\text{ feet} \\\\ \\text{1 - 1\u2033 valve @ 2.62 feet}& = 2.62\\text{ feet} \\\\ \\text{1 - 1\u2033 welded tee @ 3.93 feet}& = \\underline{3.93 \\text{ feet}} \\\\ \\text{Equivalent Fitting Length} & = 27.17\\text{ feet} \\\\ \\text{Measured Length C-A} & = \\underline{160.00 \\text{ feet}} \\\\ \\text{Longest Equivalent Length of Run (ELR)} &= 187.17\\text{ feet} \\end{array}[\/latex]<\/p>\n<p>The longest ELR is 187.17 feet, so the 200 ft code zone was correct.<\/li>\n<li>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Natural Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Welded carbon with forged fittings<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure<\/th>\n<td style=\"width: 50%;\">34 kPa<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">A.5 (b) Metric<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">17 kPa<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">30 m<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">45 m<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\">Proofed Longest (ELR)<\/th>\n<td style=\"width: 50%;\">41.03 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">293 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">805 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">3,000 kW<\/td>\n<td style=\"width: 33.3333%;\">2 in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">D<\/td>\n<td style=\"width: 33.3333%;\">1,170 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">E<\/td>\n<td style=\"width: 33.3333%;\">4,170 kW<\/td>\n<td style=\"width: 33.3333%;\">2 in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">F<\/td>\n<td style=\"width: 33.3333%;\">4,975 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]2\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">G<\/td>\n<td style=\"width: 33.3333%;\">5,268 kW<\/td>\n<td style=\"width: 33.3333%;\">[latex]2\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"text-decoration: underline;\">Proof of G &#8211; B<\/span><br \/>\n[latex]\\begin{array}{ll}\\text{2 - 2\u00bd\u2033 welded 90\u00b0 @ 0.75m}&=1.50 \\text{ m} \\\\ \\text{2 - 1\u00bd\u2033 welded tees @ 2.82 m}& = 5.64\\text{ m} \\\\ \\text{3 - 1\u00bc\u2033 welded 90\u00b0 @ 0.42 m}&=1.26 \\text{ m} \\\\ \\text{1 - 1\u00bc\u2033 valve @ 1.05 m}& = 1.05\\text{ m} \\\\ \\text{1 - 1\u00bc\u2033 welded tee @ 1.58 m}& = \\underline{1.58 \\text{ m}} \\\\ \\text{Equivalent Fitting Length} & = 11.03\\text{ m} \\\\ \\text{Measured Length C-A} & = \\underline{30.00 \\text{ m}} \\\\ \\text{Equivalent Length of Run (ELR)} &= 41.03\\text{ m} \\end{array}[\/latex]<\/p>\n<p>Additional proofs<\/p>\n<p><span style=\"text-decoration: underline;\">Proof of G-C<\/span><br \/>\n[latex]\\begin{array}{ll}\\text{2 - 2\u00bd\u2033 welded 90\u00b0 @ 0.75m}&=1.50 \\text{ m} \\\\ \\text{1 - 2\u00bd\u2033 welded tees @ 2.82 m}& = 2.82\\text{ m} \\\\ \\text{3 - 2\u2033 welded 90\u00b0 @ 0.63 m}&=1.89\\text{ m} \\\\ \\text{1 - 2\u2033 valve @ 1.58 m}& = 1.58\\text{ m} \\\\ \\text{2 - 2\u2033 welded tees @ 2.36 m}& = \\underline{4.72 \\text{ m}} \\\\ \\text{Equivalent Fitting Length} & = 12.51\\text{ m} \\\\ \\text{Measured Length C-A} & = \\underline{22.00 \\text{ m}} \\\\ \\text{Equivalent Length of Run (ELR)} &= 34.51\\text{ m} \\end{array}[\/latex]<\/p>\n<p><span style=\"text-decoration: underline;\">Proof of G-D<br \/>\n<\/span>[latex]\\begin{array}{ll}\\text{2 - 2\u00bd\u2033 welded 90\u00b0 @ 0.75m}&=1.50 \\text{ m} \\\\ \\text{1 - 2\u00bd\u2033 welded tees @ 2.82 m}& = 2.82\\text{ m} \\\\ \\text{3 - 1\u00bc\u2033 welded 90\u00b0 @ 0.42 m}&=1.26\\text{ m} \\\\ \\text{1 - 1\u00bc\u2033 valve @ 1.05 m}& = 1.05\\text{ m} \\\\ \\text{1 - 1\u00bc\u2033 welded tee @ 1.58 m}& = \\underline{1.58\\text{ m}} \\\\ \\text{Equivalent Fitting Length} & = 8.21\\text{ m} \\\\ \\text{Measured Length C-A} & = \\underline{25.00 \\text{ m}} \\\\ \\text{Equivalent Length of Run (ELR)} &= 33.21\\text{ m} \\end{array}[\/latex]<\/p>\n<p>The longest ELR is 41.03 metres, so the 45 meter code zone was correct.<\/li>\n<li>7\u2033 WC Piping System:<br \/>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Natural Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Screwed carbon steel pipe<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure &#8211; 7\u2033 WS<\/th>\n<td style=\"width: 50%;\">7\u2033 WC<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">A.2 (a) Imperial<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">1\u2033 WC<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">93 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">100 ft<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">100 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">75 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">175 MBH<\/td>\n<td style=\"width: 33.3333%;\">1 in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>2 PSG Piping System:<\/p>\n<table style=\"border-collapse: collapse; width: 100%; height: 112px;\">\n<tbody>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%; height: 16px;\">Natural Gas<\/td>\n<\/tr>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%; height: 16px;\">Screwed carbon steel pipe<\/td>\n<\/tr>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">System Pressure &#8211; 2 PSI<\/th>\n<td style=\"width: 50%; height: 16px;\">2 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\">Selected Pressure Drop &#8211; 1 PSI<\/th>\n<td style=\"width: 50%;\">1 psig<\/td>\n<\/tr>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%; height: 16px;\">A.3 (a) Imperial<\/td>\n<\/tr>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%; height: 16px;\">83 ft<\/td>\n<\/tr>\n<tr style=\"height: 16px;\">\n<th style=\"width: 50%; height: 16px;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%; height: 16px;\">90 ft<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">1<\/td>\n<td style=\"width: 33.3333%;\">300 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">2<\/td>\n<td style=\"width: 33.3333%;\">150 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">3<\/td>\n<td style=\"width: 33.3333%;\">450 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{3}{4}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>5 PSG Piping System<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Type of Gas<\/th>\n<td style=\"width: 50%;\">Natural Gas<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Piping Material<\/th>\n<td style=\"width: 50%;\">Screwed carbon steel pipe<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">System Pressure &#8211; 5 PSI<\/th>\n<td style=\"width: 50%;\">5 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Used<\/th>\n<td style=\"width: 50%;\">A.5 (a) Imperial<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Table Allowable Pressure Drop<\/th>\n<td style=\"width: 50%;\">2.5 psig<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Longest Measured Run (LMR)<\/th>\n<td style=\"width: 50%;\">84 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\" scope=\"row\">Code Zone (CZ)<\/th>\n<td style=\"width: 50%;\">125 ft<\/td>\n<\/tr>\n<tr>\n<th style=\"width: 50%;\">Proofed Longest (ELR)<\/th>\n<td style=\"width: 50%;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Letter<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Load<\/th>\n<th style=\"width: 33.3333%;\" scope=\"col\">Pipe Size<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">A<\/td>\n<td style=\"width: 33.3333%;\">5,000 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">B<\/td>\n<td style=\"width: 33.3333%;\">450 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">C<\/td>\n<td style=\"width: 33.3333%;\">5,450 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">D<\/td>\n<td style=\"width: 33.3333%;\">175 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]\\frac{1}{2}[\/latex] in<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 33.3333%;\">E<\/td>\n<td style=\"width: 33.3333%;\">5,625 MBH<\/td>\n<td style=\"width: 33.3333%;\">[latex]1\\frac{1}{4}[\/latex] in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Proof of G &#8211; B<br \/>\n[latex]\\begin{array}{ll}\\text{5 - 1\u00bc\u2033 screwed 90\u00b0 @ 3.45 ft}&=17.25 \\text{ ft} \\\\ \\text{1 - 1\u00bc\u2033 valve @ 3.45 ft}& = 3.45 \\text{ ft} \\\\ \\text{2 - 1\u00bc\u2033 screwed tees @ 6.90 ft}&=\\underline{13.80 \\text{ ft}} \\\\ \\text{Equivalent Fitting Length} & = 34.50\\text{ feet} \\\\ \\text{Measured Length C-A} & = \\underline{84.00 \\text{ feet}} \\\\ \\text{Equivalent Length of Run (ELR)} &= 118.50\\text{ feet} \\end{array}[\/latex]<\/p>\n<p>The longest ELR is 118.50 feet, so the 125 ft code zone was correct.<\/li>\n<\/ol>\n<h1>Competency E5<\/h1>\n<h2>Self-Test 1<\/h2>\n<ol class=\"threecolumn\">\n<li>A<\/li>\n<li>D<\/li>\n<li>A<\/li>\n<li>C<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>C<\/li>\n<li>D<\/li>\n<li>B<\/li>\n<\/ol>\n<h2>Self-Test 2<\/h2>\n<ol class=\"twocolumn\">\n<li>A<\/li>\n<li>B<\/li>\n<li>A<\/li>\n<li>B<\/li>\n<li>C<\/li>\n<li>A<\/li>\n<li>Match the names of the burner parts to their<br \/>\nlettered locations<\/p>\n<ul>\n<li>Venturi D<\/li>\n<li>Mixing Tube C<\/li>\n<li>Burner Ports A<\/li>\n<li>Orifice E<\/li>\n<li>Burner Head B<\/li>\n<li>Primary air openings F<\/li>\n<\/ul>\n<\/li>\n<li>B<\/li>\n<li>A<\/li>\n<li>C<\/li>\n<li>C<\/li>\n<li>A<\/li>\n<li>A<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<\/ol>\n<h2>Self-Test 3<\/h2>\n<ol class=\"threecolumn\">\n<li>C<\/li>\n<li>B<\/li>\n<li>D<\/li>\n<li>D<\/li>\n<li>B<\/li>\n<li>D<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>C<\/li>\n<li>D<\/li>\n<li>B<\/li>\n<li>A<\/li>\n<li>C<\/li>\n<li>B<\/li>\n<li>A<\/li>\n<\/ol>\n<h1>Competency E6<\/h1>\n<h2>Self-Test 1<\/h2>\n<ol class=\"threecolumn\">\n<li>D<\/li>\n<li>C<\/li>\n<li>D<\/li>\n<li>B<\/li>\n<\/ol>\n<h2>Self-Test 2<\/h2>\n<ol class=\"threecolumn\">\n<li>B<\/li>\n<li>B<\/li>\n<li>C<\/li>\n<li>B<\/li>\n<li>A<\/li>\n<li>A<\/li>\n<li>A<\/li>\n<li>C<\/li>\n<\/ol>\n<h2>Self-Test 3<\/h2>\n<ol class=\"threecolumn\">\n<li>C<\/li>\n<li>C<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<li>C<\/li>\n<li>D<\/li>\n<li>B<\/li>\n<li>B<\/li>\n<\/ol>\n","protected":false},"author":123,"menu_order":1,"template":"","meta":{"pb_show_title":"on","pb_short_title":"","pb_subtitle":"","pb_authors":[],"pb_section_license":""},"back-matter-type":[29],"contributor":[],"license":[],"class_list":["post-175","back-matter","type-back-matter","status-publish","hentry","back-matter-type-appendix"],"_links":{"self":[{"href":"https:\/\/opentextbc.ca\/plumbing3e\/wp-json\/pressbooks\/v2\/back-matter\/175","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/opentextbc.ca\/plumbing3e\/wp-json\/pressbooks\/v2\/back-matter"}],"about":[{"href":"https:\/\/opentextbc.ca\/plumbing3e\/wp-json\/wp\/v2\/types\/back-matter"}],"author":[{"embeddable":true,"href":"https:\/\/opentextbc.ca\/plumbing3e\/wp-json\/wp\/v2\/users\/123"}],"version-history":[{"count":0,"href":"https:\/\/opentextbc.ca\/plumbing3e\/wp-json\/pressbooks\/v2\/back-matter\/175\/revisions"}],"metadata":[{"href":"https:\/\/opentextbc.ca\/plumbing3e\/wp-json\/pressbooks\/v2\/back-matter\/175\/metadata\/"}],"wp:attachment":[{"href":"https:\/\/opentextbc.ca\/plumbing3e\/wp-json\/wp\/v2\/media?parent=175"}],"wp:term":[{"taxonomy":"back-matter-type","embeddable":true,"href":"https:\/\/opentextbc.ca\/plumbing3e\/wp-json\/pressbooks\/v2\/back-matter-type?post=175"},{"taxonomy":"contributor","embeddable":true,"href":"https:\/\/opentextbc.ca\/plumbing3e\/wp-json\/wp\/v2\/contributor?post=175"},{"taxonomy":"license","embeddable":true,"href":"https:\/\/opentextbc.ca\/plumbing3e\/wp-json\/wp\/v2\/license?post=175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}